4-16
6. REMOTE STATION (Default setting: ON)
This setting item determines whether DSC-60 is operated as remote station or not. This item is set at
ON or OFF. If it is set at OFF, the remote function can not be switched by [1/RT/2182] key.
7. NBDP PORT (Default setting: OFF)
If FS-75/1562 or FS-5000 series is connected to Furuno NBDP, DP-5/6, set this item at ON. Then,
the control of the NBDP can be made by the MIF protocol.
Whereas MAIN and MODEM CPU programs are updated from IB-581 or PC, NBDP Port setting is
disregarded. At this time, however, set DIP switch S3-12 at ON.
Note) Related settings
Select RS-232C, RS-422, or Current Loop by DIP switches S4 and S5 on CONTROL/
MODEM board. Refer to the following table.
The pin assignment of NBDP connector for MIF data is different from those for
IEC data.
8. LANGUAGE (Fixed to ENGLISH)
For future use. This item is used to select the language for DSC display. At moment, English only.
2. System setup(System setup)
1/RT/2182
ON
2/DSC/ABC
ON
ON REMOTE STATION DSC
OFF DSC DSC
FUNCTION
SETTING
J7
J6
J1
J3 J8 J9
J4
J5
U5 U11
S1
NMI SW
EEPROM
05P0702
S5
S2S3S4
(RT)
PORT Specifications S6,7,8 Protocol Remarks SYSTEM setting
1,2 RS-232C DP-5 and DP-6
TRS-422
ON RS-422
OFF C.Loop
S5 ON/OFF T/R DATA
T/R:RS-232C-
S2,3,4
S3
3,4 RS-422
ONMIF-NBDP
-
S5-1 R
-