2. OPERATION
2-30
2.15.4 How to use the input/output logs
The [I/O LOGS] display logged data for input/output information for serial ports and
LAN connections. You can export the logged data to an external flash memory.
The following keys have specific functions when a log screen appears.
Saved log files are automatically named in the following format:
The log data which can be saved depends on the monitor type selected.
[DATA1] to [DATA5] - Serial data
Key Function
W Close the log and return to the [I/O] menu.
S or T Toggle input and output log displays.
ENT Press with external flash memory connected: start/pause saving the log.
MENU ESC Close the logs and the [I/O] menu.
This
equipment’s
name
The log type
Tx = ouput
Rx = input
Time and date when the log was saved.
Displayed in YYYYMMDDHHMMSS
format.
The logged port. Displayed in the filename as follows:
DATA 1 to DATA 5 : Data from serial port 1 to 5.
Network : Data from the connected LAN network.
CANbus : PGN data from the CAN bus network.
RAW : Raw data from the connected antenna.
Selected port and port’s baud rate
Currently displayed data
TX = Output data
RX = Input data
USB status
No USB = No external
flash memory connected.
SAVING = Saving log
data to external flash
memory.
STOP SAVING = Flash
memory connected, no
log data currently being
saved.
Logged input/output data
is displayed here.

Table of Contents