2. OPERATION
2-34
2.16.2 SENSOR STATUS menu
You can check the status of your sensors from this menu. Select [SENSOR STATUS]
from the [SENSOR] menu to show the window below.
Possible statuses for each item are listed in the table below.
2.17 SYSTEM Menu
The SYSTEM menu contains settings for your SC-70/
SC-130 system. To access this menu, open the
[MENU] then select [SYSTEM].
Note 1: The [USB FLASH DRIVE] menu item is se-
lectable only when a USB Flash Memory is connected
to the Junction Box.
Note 2: The [NETWORK] menu item is reserved for
technical personnel only and require password level
access from the [SERVICE] menu.
No. Possible status
1 • "OK": Sensor is functioning normally.
• "NG (axis)": The sensor is not functioning normally on the axis shown. For ex-
ample, "NG X,Y" means the X and Y axis are not functioning normally.
2 • "OK": Sensor is functioning normally.
• "NG (axis)": The sensor is not functioning normally on the axis shown. For ex-
ample, "NG X,Y" means the X and Y axis are not functioning normally.
3 • "NORMAL": Sensor is functioning normally.
• "DR": Dead Reckoning in use.
• "OUTPUT STOPPED": Sensor output has stopped.
• "NOT EXPECTED": An unexpected error has occurred.
4 Hexadecimal code is displayed.
5 • "OK": Sensor is functioning normally.
• "BLOCKED": One or more sensors’ line of view is blocked.
• "VIBRATED": One or more sensors are in a location which is subject to ex-
cessive vibrations.
OK
OK
NORMAL
000000
OK