SwashBasicSwashBasic
(14) Pit.
High: Pitch high memorizing
This parameter saves the full positive collective pitch point into the CGY.
[Setting method] Touch the "Pit. High" rate button to enter the setting
mode. Operate the throttle stick fully to the high. Touch the “Pit. High” rate
button again. ”Sure?” Is displayed. If you touch the [Yes] button. The full
positive pitch signal will be saved to the CGY.
(15) Pit. Zero: Pitch zero memorizing
This parameter saves the zero collective pitch point into the CGY.
[Setting method] Touch the "Pit. Zero" rate button to enter the setting
mode. Operate the throttle stick to 0 degree pitch. Touch the “Pit. Zero” rate
button again. “Sure?” Is displayed. If you touch the [Yes] button. The zero
pitch signal will be saved to the CGY.
(16) Pit. Low: Pitch low memorizing
This parameter saves the full negative collective pitch point into the CGY.
[Setting method] Touch the "Pit. Low" rate button to enter the setting
mode. Operate the throttle stick fully to the low. Touch the “Pit. Low” rate
button again. “Sure?” Is displayed. If you touch the [Yes] button. The full
negative pitch signal will be saved to the CGY.