______________________________________________________________________________
____________________________________________________________________________
Page 7-48 LMM for the Kodiak 100
190-02102-00 Rev.4
12. Press ENT. If a previous CALIBRATION VALUE exists, a prompt will appear
requesting overwrite acknowledgment. If prompted, select YES and press ENT.
An ACTUAL QUANTITY of 0.00 lb. and a CALIBRATED VALUE will appear in the
CALIBRATION TABLE.
13. Monitor the CALIBRATED TOTAL indication in the lower right-hand corner. Make
sure it remains at 0.00 lb. ±1.0 lb.
14. Turn off the cursor by pressing the FMS knob, and turn the outer FMS knob to
select SYSTEM page group.
15. Turn the inner knob to select SYSTEM UPLOAD page. Press the UPDT CFG
softkey. A prompt appears asking to UPDATE CONFIG MODULE. Select YES
and press ENT.
16. After UPDATE CONFIG COMPLETE appears, press the ENT key to select OK.
7.12.2.3 Full Calibration
1. Place the aircraft in a 2.7° ± 0.2° nose up and 0.0° ± 0.1° roll attitude, to simulate
an reflect normal ground attitude.
2. Fill the fuel tanks to the bottom of the outboard filler cap with Jet A or Jet A1 fuel,
ensuring the aircraft remains in a 2.7° ± 0.2° nose up and 0.0° ± 0.1° roll attitude.
A full tank is defined as just enough fuel to cover the anti-siphon flapper valve
with a thin (1/16" - 1/8") film of fuel.
3. Allow the system to stabilize for a minimum of three minutes.
4. If not already performed, turn all three displays on in Configuration mode by
pushing and holding the ENT key on each display, while applying display power.
Release the ENT key after INITIALIZING SYSTEM appears in the upper left
corner of the display.
5. On PFD #1, go to the CAL page group, FUEL TANK CALIBRATION page.
6. If not already performed, on PFD #1, enter pass code: softkeys 12, 11, 10, 9 by
pressing each softkey sequentially.
7. With the LEFT selected as the CURRENT TANK, press the FULL softkey. The
cursor will automatically activate and select the CALIBRATE? option.
8. Press ENT. If a previous CALIBRATION VALUE exists, a prompt appears
requesting overwrite acknowledgment. If prompted, select YES and press ENT.
An ACTUAL QUANTITY of 1056.87 lb. and a CALIBRATED VALUE will appear in
the CALIBRATION TABLE.
9. Check the CALIBRATED TOTAL indication in the lower right-hand corner. Make
sure it remains at 1056.87 lb. ±1.0 lb.
Uncontrolled if Printed

Table of Contents

Other manuals for Garmin G1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Garmin G1000 and is the answer not in the manual?

Garmin G1000 Specifications

General IconGeneral
Display TypeLCD
Primary Flight Display (PFD)Yes
Multi-Function Display (MFD)Yes
Terrain AwarenessYes
Autopilot IntegrationYes
Integrated Flight Deck SystemYes
Weather RadarOptional
Traffic Advisory System (TAS)Optional
Terrain Awareness and Warning System (TAWS)Yes
Resolution1024 x 768 pixels
Weather DataYes
NavigationYes
AHRSYes
Air Data Computer (ADC)Yes
InterfacesARINC 429, RS-232
CertificationTSO certified
Traffic InformationOptional (requires ADS-B or TCAS)