8.1 Suggested Cleaning and Maintenance Supplies
Cleaning / Maintenance Tool
Special notes
Soap Solution or All-Purpose Cleaner
Paper Towels
Cotton Cloth
Denatured Alcohol
DO NOT use alcohol on any painted surface,
plastic, or the laser system!
Acetone
ONLY to be used on the working table
Vacuum Cleaner with a Flexible Nozzle
Only to be used in and around the worktable
and motion system
Light Grade Machine Oil
Cotton Swabs
Supplied
Lens Cleaner
Supplied
Lint Free Lens Tissue
Supplied
#2 Phillips Screwdriver
Allen Wrench .050”
8.2 Maintaining the Worktable and Motion System
8.2.1 Accessing the Worktable and Motion System
Remove the screws of the top of the machine and lift the top off
8.2.2 Cleaning the Worktable and Motion System
Clean the working table and the motion system on a frequent basis through the following steps:
1) Turn the power off and unplug the X380 before cleaning.
2) Use a vacuum cleaner with a flexible nozzle to remove dust and debris from the worktable and
motion system.
3) Apply small amounts of all-purpose cleaner, alcohol, or acetone to a paper or cotton towel to
clean the working table.
4) Apply a soap solution, all-purpose cleaner, or alcohol to a paper or cotton towel to wipe down the
rails of the motion system.
5) Wait for all cleaning residue to dry completely before plugging in and operating the X380.
CAUTION
Never pour or spray alcohol or acetone directly to the working table.
Oil, alcohol and acetone can cause fires or smoke build-up if improperly used.