31
Note
Call-waiting services should
be disabled to prevent inter-
rupting panel communica-
tion to the pager(s). To
program a dialing prefix that
disables call-waiting, see the
Call Wait Cancel setting
under the menu
PHONE
OPTIONS—GLOBAL
.
To enter pauses, press C.
To enter *, press and hold 7 for about two seconds.
To enter #, press and hold 9 for about two seconds.
¾
To program a Pager Phone Number:
With the display showing PHONE NUMBER _ (or current number), enter the desired pager
phone number. The display flashes the entered number. Press # and the display shows the
new setting.
¾
To delete a Pager Phone Number:
With the display showing PHONE NUMBER (current number), press D. The display shows
PHONE NUMBER _.
High Level Rpts (Phones—Pager Phone 1-5)
(pager 1: 0131, pager 2: 0141, pager 3: 0151, pager 4: 0161, pager 5: 0171)
(Default = on) This setting determines whether the following alarm conditions report to a pager:
Fire, Police, Auxiliary, and Duress alarms
No Activity
Receiver Failure (or jam)
Tamper conditions, including Zone Tampers and System Tamper (40 incorrect key presses or
touchpad supervisory)
Entering or exiting Sensor Test mode
Phone Test
¾
To turn High-Level Reports off or on:
With the display showing HIGH LEVEL RPTS OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
Low Level Rpts (Phones—Pager Phone 1-5)
(pager 1: 0132, pager 2: 0142, pager 3: 0152, pager 4: 0162, pager 5: 0172)
(Default = off) This setting determines whether the following non-alarm conditions report to a
pager:
•Force Armed
Hardwire Zone Trouble (open or short)
Supervisory (wireless devices)
Low Battery (wireless devices)
Phone Test
Other non-alarm related conditions
¾
To turn Low-Level Reports off or on:
With the display showing LOW LEVEL RPTS OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
Exception Rpts (Phones—Pager Phone 1-5)
(pager 1: 0133, pager 2: 0143, pager 3: 0153, pager 4: 0163, pager 5: 0173)
(Default = off) This setting determines whether the panel reports to a pager if the system is not
armed or disarmed at the specified schedule times, if open/close reports are turned on.
¾
To turn Exception Reports off or on:
With the display showing EXCEPTION RPTS OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
Open/Close Rpts (Phones—Pager Phone 1-5)
(pager 1: 0134, pager 2: 0144, pager 3: 0154, pager 4: 0164, pager 5: 0174)
Note
To use this feature, the
opening reports and closing
reports settings under the
REPORTING menu must be
turned on for that partition.
(Default = off) This setting determines whether opening and closing reports are sent to a pager.
When turned on, the panel sends a closing report when the system is armed and an opening report
when the system is disarmed.
¾
To turn Opening/Closing Reports off or on:
With the display showing OPEN/CLOSE RPTS OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press
# and the display shows the new setting.