33
Auto Phone Test (Phone Options—Global)
(02001)
Note
For U.L. Commercial Listed
installations (UL 1610), this
feature must be on.
(Default = off) This setting determines if the panel sends a phone test automatically to the central
station or a pager on a predetermined schedule. (Refer to the “Phone Test Freq.” and “Next
Phone Test” settings found under TIMERS—GLOBAL).
¾
To turn Automatic Phone Test off or on:
With the display showing AUTO PHONE TEST OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
Auto Test Reset (Phone Options—Global)
(02002)
(Default = on) This setting determines whether or not the Auto Phone Test interval is reset after
any successful report to the central monitoring station. (Refer to the “Phone Test Freq.” and
“Next Phone Test” settings found under TIMERS—GLOBAL).
When this feature is on, the panel considers any successful report to the central monitoring sta-
tion to be a successful phone test. Thus, any panel report resets the Next Phone Test setting to the
Phone Test Freq. value. The panel only conducts an Auto Phone Test if no other reports have
been made during the Phone Test Freq. time period.
Note
Phone Test Freq must be set
to 2 or higher for Auto Test
Reset to work.
When this feature is off, an Auto Phone Test is always conducted according to the schedule of the
Phone Test Freq. setting, even if the panel makes other reports to the central monitoring station
during that time period.
¾
To turn Auto Test Reset off or on:
With the display showing AUTO TEST RESET OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press
# and the display shows the new setting.
Comm Failure (Phone Options—Global)
(02003)
Note
For UL Listed installations,
Comm Failure must be
turned on.
(Default = on) This setting determines whether the panel activates trouble beeps to alert users on
the premises that communication to the central station failed. Failure notification occurs after the
third unsuccessful reporting attempt to the central station/pager.
If a Phone Supervision Card (60-789) is installed, failure notification can occur immediately if
inadequate phone line voltage is detected upon the initial dialing attempt.
¾
To turn Communication Failure notification off or on:
With the display showing COMM FAILURE OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
DTMF Dialing (Phone Options—Global)
(02004)
(Default = on) This setting determines whether the panel uses DTMF tones (on) or pulse (off) for
dialing programmed phone numbers.
¾
To turn DTMF Dialing off or on:
With the display showing DTMF DIALING OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
Dialer Abort (Phone Options—Global)
(02005)
(Default = on) This setting determines whether or not the user can stop a panel before it sends a
false alarm to the central station.
Note
Fire alarm reports to the
central station cannot be
aborted.
When this feature is on, alarm reports from sensors in groups 00–20, 34, and 35 can be aborted.
To abort the dialing attempt, the user must enter 1 + user
code within the Dialer Abort Delay time
setting (defaulted to 30 sec). Cancel and restoral reports from these sensor groups are aborted at
the same time. The following reports can also be aborted.
System Alarm Tamper/Cancel
No Activity Alarm/Cancel
Touchpad Police and Auxiliary Panic/Cancel
Recent Closing and Two Trip Error
¾
To turn Dialer Abort off or on:
With the display showing DIALER ABORT OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.