34
Dial Abort Delay (Phone Options—Global)
(02006)
(Default = 30 sec) This setting determines how much time the user has to abort a panel report.
¾
To change the Dial Abort Delay:
With the display showing DIAL ABORT DELAY nn SECS (current setting), enter the desired time
(15–120s). The display flashes the entered setting. Press # and the display shows the new
setting.
Cancel Message (Phone Options—Global)
(02007)
Default = on) This setting determines whether or not the panel displays a cancel message after
the user disarms the system to clear an alarm condition.
¾
To turn Cancel Message off or on:
With the display showing CANCEL MESSAGE OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
Pager Delay (Phone Options—Global)
(02008)
Note
The Pager Delay time
should not be set below 5
seconds, unless absolutely
necessary.
(Default = 15 sec) This setting determines how long a report is delayed to a pager, after the panel
dials the pager number.
¾
To set the Pager Delay time:
With the display showing PAGER DELAY nn SECS (current setting), enter a delay time (0–30).
The display flashes the entered setting. Press # and the display shows the new setting.
Call Wait Cancel (Phone Options—Global)
(02009)
(Default = none) This feature lets you set up a dialing prefix to disable the call waiting feature
before the panel makes its first dialing attempt to any programmed central monitoring station or
downloader phone number. The prefix can be up to eight digits.
To enter pauses, press C.
To enter *, press and hold 7 for one second.
To enter #, press and hold 9 for one second.
¾
To set up Call Wait Cancel:
With the display showing CALL WAIT CANCEL __ (or current setting), enter the desired prefix.
The display flashes the entered setting. Press # and the display shows the new setting.
¾
To delete the Call Wait Cancel prefix:
With the display showing CALL WAIT CANCEL __ (or current setting), press D.
Dial Tone Detect (Phone Options—Global)
(02010)
Note
There is no Dial Tone Detect
on the last dialing attempt.
(Default = on) When this setting is on, the panel begins dialing as soon as it detects a dial tone.
When this feature is off, the panel begins dialing a few seconds after seizing the phone line.
¾
To set up Dial Tone Detect:
With the display showing DIAL TONE DETECT OFF/ON (current setting), press 1 (off) or 2
(on). The display flashes the entered setting. Press # and the display shows the new setting.
The following sections describe the phone option settings that appear under
PARTITION 1-2.
A Phone Interface/Voice module must be installed for the system to use the settings under
PHONE
OPTIONS— PARTITION 1-2.
Local Phone Control (Phone Options—Partition 1-2)
(partition 1: 0210, partition 2: 0220)
(Default = on) When this feature is on, the panel can be accessed from a phone on the premises.
¾
To set up Local Phone Control:
With the display showing LOCAL PHONE CTRL OFF/ON (current setting), press 1 (off) or 2
(on). The display flashes the entered setting. Press # and the display shows the new setting.