35
Remote Access (Phone Options—Partition 1-2)
(partition 1: 0211, partition 2: 0221)
(Default = on) When this setting is on, the panel can be accessed from an off-site phone.
¾
To turn Remote Access off or on:
With the display showing REMOTE ACCESS OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
Ring/Hang/Ring (Phone Options—Partition 1-2)
(partition 1: 0212, partition 2: 0222)
(Default = on) This setting determines how the panel picks up (seizes) the phone line. Select “on”
if an answering machine shares the phone line with the panel. Select “off” if there is no answer-
ing machine sharing the phone line with the panel.
Note
The Remote Access setting
must be turned on for this
feature to work.
When this feature is on, the person who is calling the panel must use the following procedure:
1. Listen for one or two full rings.
2. Hang up.
3. Call the premises again within the next 10–40 seconds. The system answers after the first
ring.
When this feature is off, the system answers after 12 full rings.
¾
To turn Ring/Hang/Ring access off or on:
With the display showing RING/HANG/RING OFF/ON (current setting), press 1 (off) or 2 (on).
The display begins flashing the entered selection. Press # and the display shows the new set-
ting.
Line Fail Delay (Phone Options—Partition 1 only)
(partition 1: 0213)
(Default = none) This setting determines the amount of time the partition 1 phone line voltage
must be absent before the panel indicates a phone failure trouble condition. If a delay is not pro-
grammed (default), the panel will not monitor the phone line voltage.
Note
Line Fail Delay is not avail-
able for partition 2 at this
time.
A Phone Supervision Card
must be installed to use this
feature.
¾To set the Line Fail Delay time:
1. With partition 1 selected, press A or B until the display shows LINE FAIL DELAY nn SECS (cur-
rent setting).
2. Enter the desired time value (10–240 seconds). The display flashes the entered setting. Press
# and the display shows the new setting.
¾
To delete the Line Fail Delay time:
1. With partition 1 selected, press A or B until the display shows LINE FAIL DELAY nn SECS (cur-
rent setting).
2. Press D to delete the current line fail delay time.
Toll Saver (Phone Options—Partition 1-2)
(partition 1: 0214, partition 2: 0224)
(Default = on) This setting determines whether the panel answers a phone call on the eighth ring
(on) or twelfth ring (off) when a trouble condition exists.
¾
To turn Toll Saver off or on:
1. With the desired partition selected, press A or B until the display shows TOLL SAVER OFF/ON
(current setting).
2. Press 1 (off) or 2 (on). The display flashes the entered setting. Press # and the display shows the
new setting.
Phone Panic (Phone Options—Partition 1-2)
(partition 1: 0215, partition 2: 0225)
(Default = off) This setting determines whether or not a police panic alarm can be activated from
a touch-tone phone. When this feature is on, pressing # + ****** from a touch-tone phone on the
premises causes a panic alarm.
¾
To turn Phone Panic off or on:
1. With the desired partition selected, press A or B until the display shows PHONE PANIC OFF/
ON
(current setting).
2. Press 1 (off) or 2 (on). The display flashes the entered setting. Press # and the display shows
the new setting.