40
24-Hour Tamper (Reporting—Global)
(06000)
Note
For commercial UL Listed
installations (UL 1610) the
24-Hour Tamper must be set
to on.
(Default = off) When this setting is on, the panel sounds sirens and reports a tamper alarm (even
when the system is disarmed), when wireless sensor tamper switches are activated.
¾
To turn 24-Hour Tamper off or on:
With the display showing 24 HOUR TAMPER OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
Buffer Control (Reporting—Global)
(06001)
(Default = off) When this setting is on, only arming level changes are logged in the buffer (mem-
ory) of the panel. When this setting is off, all system events are logged in the buffer.
¾
To turn Buffer Control off or on:
With the display showing BUFFER CONTROL OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
Back In Service (Reporting—Global)
(06002)
(Default = on) When this setting is on, the panel reports to the central station when AC and
backup battery power are restored (after an extended power outage).
¾
To turn Back In Service reports off or on:
With the display showing BACK IN SERVICE OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
Bypass Reports (Reporting—Global)
(06003)
(Default = off) When this setting is on, the panel reports to the central station whenever sensors
or zones are bypassed.
¾
To turn Bypass Reports off or on:
With the display showing BYPASS REPORTS OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
Low CPU Battery (Reporting—Global)
(06004)
(Default = on) When this setting is on, the panel reports a low panel battery to the central station
before shutting down.
Note
For UL Listed installations,
the Low CPU Battery feature
must be set to on.
¾To turn Low CPU Battery reports off or on:
With the display showing LOW CPU BATTERY OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.
Battery Restoral (Reporting—Global)
(06005)
(Default = off) If this setting is on, the panel reports to the central monitoring station when a
wireless sensor or touchpad reports a battery replacement to the panel.
¾
To turn Battery Restoral reports off or on:
With the display showing BATTERY RESTORAL OFF/ON (current setting), press 1 (off) or 2
(on). The display flashes the entered setting. Press # and the display shows the new setting.
Buffer Full Rpt (Reporting—Global)
(06006)
(Default = off) When this setting is on, the panel sends an “event buffer full” report to the central
monitoring station when the event buffer is nearly full.
¾
To turn Buffer Full Report off or on:
With the display showing BUFFER FULL RPT OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting.