42
RF Supv Report (Reporting—Global)
(06013)
(Default = weekly) This setting determines whether the panel sends daily or weekly reports to the
central monitoring station when the panel detects a supervisory condition in a wireless device.
¾
To set RF Supv Report to daily or weekly:
With the display showing RF SUPV REPORT DAILY/WEEKLY (current setting), press 1 (daily)
or 2 (weekly). The display flashes the entered setting. Press # and the display shows the new
setting.
Swinger Limit (Reporting—Global)
(06014)
(Default = 1) This setting determines the maximum number of times (1–2) a sensor or zone can
go into alarm (during a single arming period) before the panel automatically bypasses that sensor
or zone. This feature only applies to sensors or zones in groups 00–20, 29, 34, or 35.
When set to 1, the panel automatically bypasses a sensor or zone after it causes an alarm. When
set to 2, the panel waits until a sensor or zone has caused a second alarm (during the same arming
period) before bypassing it. At any setting, the automatic bypass is logged into the event buffer.
A bypassed sensor or zone will be cleared (automatically unbypassed) if the system receives no
further activations from that sensor or zone over the next 48–50 hours.
Changing the arming level also clears all automatically bypassed sensors and zones and resets the
Swinger Limit count on all sensors and zones.
¾
To set the Swinger Limit:
With the display showing SWINGER LIMIT n (current setting), press the desired number (1–2).
The display flashes the entered setting. Press # and the display shows the new setting.
Program Report (Reporting—Global)
(06015)
(Default = off) When this setting is on, the panel sends a report to the central station when some-
one enters or exits installer programming.
¾
To turn Program Report on or off:
With the display showing PROGRAM REPORT ON/OFF (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting. Press # and the display shows the new setting
The following sections describe the settings that appear under
REPORTING—PARTITION 1-2.
Opening Reports (Reporting—Partition 1-2)
(partition 1: 06100, partition 2: 06200)
Note
To use this feature, the
Open/Close Reports set-
tings under the
PHONES
menu must be turned on for
the specific CS Phone or
Pager number.
(Default = off) When this setting is on, the panel sends an opening report to the central station
after disarming the system.
¾
To turn Opening Reports off or on:
With the display showing OPENING REPORTS OFF/ON (current setting), press 1 (off) or 2
(on). The display flashes the entered setting. Press # and the display shows the new setting.
Closing Reports (Reporting—Partition 1-2)
(partition 1: 06101, partition 2: 06201)
Note
To use this feature, the
Open/Close Reports set-
tings under the
PHONES
menu must be turned on for
the specific CS Phone or
Pager number.
(Default = off) When this setting is on, the panel sends a closing report to the central station after
arming the system.
¾
To turn Closing Reports off or on:
With the display showing CLOSING REPORTS OFF/ON (current setting), press 1 (off) or 2
(on). The display flashes the entered setting. Press # and the display shows the new setting.
Recent Closings (Reporting—Partition 1-2)
(partition 1: 06102, partition 2: 06202)
(Default = on) When this setting is on, the panel sends a recent closing report to the central sta-
tion if an alarm occurs within two minutes after the exit delay time expires. Such a report is used
to identify a possible exit fault.
¾
To turn Recent Closings off or on:
With the display showing RECENT CLOSINGS OFF/ON (current setting), press 1 (off) or 2
(on). The display flashes the entered setting. Press # and the display shows the new setting.