1. Check that panel is powered up.
2. Check for touchpad power and/or bus miswiring, opens, or shorts.
3. Check touchpad brightness setting (see the user-programming OPTIONS menu in the “Program-
ming” section).
Touchpad buttons don’t beep when pressed.
1. Check for touchpad power and/or bus miswiring, opens, or shorts.
2. Check that key beeps option is set to on (see the ACCESSORY MODULES—BUS DEVICES menu in
the “Programming” section).
Fixed Display Touchpads
Display is lit but does not respond to key presses.
Touchpad is not connected to panel bus terminals or is wired incorrectly. Check and correct wiring.
Display is blank.
1. Check that panel is powered up.
2. Check for touchpad power and/or bus miswiring, opens, or shorts.
3. Check touchpad brightness setting (see the user-programming OPTIONS menu in the “Program-
ming” section).
Touchpad buttons don’t beep when pressed.
1. Check for touchpad power and/or bus miswiring, opens, or shorts.
2. Check that key beeps option is set to on (see the ACCESSORY MODULES—BUS DEVICES menu in
the “Programming” section).
Speakers
Speakers don’t sound alarms.
1. Check for correct wiring at speaker and panel terminals; correct where necessary.
2. Speaker output has shut down because panel detected terminal 7 or 8 is shorted to ground.
Disconnect panel AC and battery backup power. Locate short and correct. Apply panel AC and
backup battery power and retest.
3. Alarm is in partition 2 and speaker is connected to panel terminals 7 and 8, which activate only
for partition 1 alarms.
Sirens
Piezo sirens connected to SnapCard, or onboard (panel) outputs 1 and/or 2 don’t produce any alarm sounds.
1. Check for incorrect wiring between siren and panel; correct where necessary.
2. Output has not been configured (set up) to activate sirens. Enter program mode and configure
output (see ACCESSORY MODULES—BUS DEVICES—SNAP CARD, or ONBOARD OPTIONS—
OUTPUT 1, 2 in the “Programming” section).
Supervised Wireless Sirens
Sirens don’t produce any sounds and LED doesn’t respond.
1. Check to make sure siren is not plugged into an outlet controlled by a switch. Move siren to a
nonswitched outlet location and test.
2. Panel doesn’t have a Power Line Carrier (PLC) card installed. Install PLC card.
3. Panel is not powered by a power line carrier transformer. Replace existing transformer with a
power line carrier transformer.
4. Power transformer and sirens are not plugged into outlets on the same electrical phase.
Relocate sirens at different outlets to determine working locations.
5. Siren is programmed with incorrect partition house code. Clear siren house code by pressing
and holding siren button for 20 seconds. Reprogram with correct partition house code and
retest. See “Installing Supervised Wireless Sirens” (60-736-95) on page 10 for more informa-
tion.
6. Siren house code is not programmed into panel. Enter program mode and set SWS and parti-
tion house codes.
Supervised Wireless Sirens (continued)
Siren only works part of the time and/or at odd, irregular intervals.
Check that siren and/or panel transformer is not plugged into an outlet shared with a major appli-
ance, television, or computer which may generate noise and degrade the line carrier signal.
Hardwire Zones
Feature Problem Action/Solution