Concord 46
The following sections describe the settings that appear under REPORTING—PARTITION 1-2.
Program Report (06015)
Reporting-Global (Default = off)
When this setting is on, the panel sends a report to the central sta-
tion when someone enters or exits installer programming.
¾
To turn Program Report on or off:
1. With the display showing PROGRAM REPORT ON/
OFF
(current setting), press 1 (off) or 2 (on). The
display flashes the entered setting.
2. Press # and the display shows the new setting.
Opening Reports (partition 1: 06100, partition 2: 06200)
Reporting-Partition 1-2 (Default = off)
When this setting is on, the panel sends an opening report to the central
station after disarming the system.
Note
To use this feature, the Open/Close Reports settings under the
PHONES
menu must be turned on for the specific CS Phone or Pager number.
¾To turn Opening Reports off or on:
1. With the display showing OPENING REPORTS
OFF/ON
(current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.
2. Press # and the display shows the new setting.
Closing Reports (partition 1: 06101, partition 2: 06201)
Reporting-Partition 1-2 (Default = off)
When this setting is on, the panel sends a closing report to the central
station after arming the system.
Note
To use this feature, the Open/Close Reports settings under the
PHONES
menu must be turned on for the specific CS Phone or Pager number.
¾To turn Closing Reports off or on:
1. With the display showing CLOSING REPORTS
OFF/ON
(current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.
2. Press # and the display shows the new setting.
Recent Closings (partition 1: 06102, partition 2: 06202)
Reporting-Partition 1-2 (Default = on)
When this setting is on, the panel sends a recent closing report to the
central station if an alarm occurs within two minutes after the exit
delay time expires. Such a report is used to identify a possible exit
fault.
¾
To turn Recent Closings off or on:
1. With the display showing RECENT CLOSINGS
OFF/ON
(current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.
2. Press # and the display shows the new setting.
No Activity (partition 1: 06103, partition 2: 06203)
Reporting-Partition 1-2 (Default = off)
When this setting is on, the panel sends a no activity report to the cen-
tral station when the activity timeout expires (see
TIMERS—ACTIVITY TIM-
EOUT).
¾
To turn No Activity reports off or on:
1. With the display showing NO ACTIVITY OFF/ON
(current setting), press 1 (off) or 2 (on). The dis-
play flashes the entered setting.
2. Press # and the display shows the new setting.
Duress Option (partition 1: 06104, partition 2: 06204)
Reporting-Partition 1-2 (Default = off)
(Default = off) When this setting is on, the system can be controlled
using a programmed duress code (see
SECURITY—PARTITION N—DURESS
CODE
).
Note
For UL Listed installations, Duress Option must be set to off.
Do not use a duress code unless it is absolutely necessary. Using duress
codes often results in false alarms due to code entry errors. If a duress
code is absolutely necessary, use it with the audio verification module
to reduce false alarms and accidental dispatches.
¾
To turn Duress Option off or on:
1. With the display showing DURESS OFF/ON (cur-
rent setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new setting.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Interlogix Concord Security System and is the answer not in the manual?

GE Interlogix Concord Security System Specifications

General IconGeneral
BrandGE Interlogix
ModelConcord Security System
CategorySecurity System
LanguageEnglish

Related product manuals