Concord
47
Force Armed (partition 1: 06105, partition 2: 06205)
Reporting-Partition 1-2 (Default = off)
When this setting is on, the panel reports to the central monitoring station when a
user “force arms” the system.
Note
Forced arming occurs if the user presses BYPASS when arming the system with open
sensors or zones protesting.
Auto-forced arming occurs if the user does not press
BYPASS (when arming the system with open sensors/zones protesting) and the siren
time expires.
Auto-forced arming always reports to the central monitoring station.
¾To turn Force Armed off or on:
1. With the display showing FORCE
ARMED OFF/ON (current setting),
press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the
new setting.
Latchkey Format (partition 1: 06106, partition 2: 06206)
Reporting-Partition 1-2 (Default = off)
(Default = off) This setting determines whether the selected partition is set up for
basic (off) or advanced (on) latchkey opening report operation.
Basic:
If the partition is armed by entering 2 (or
3) + CODE, disarming using a desig-
nated latchkey user code or keychain touchpad within an assigned time schedule
sends a page.
If the partition is armed by entering 2 (or
3) + CODE + 6 (Latchkey), disarming
using a designated latchkey user code or keychain touchpad inside or outside of
an assigned time schedule sends a page.
Advanced:
If the partition is armed by entering 2 (or
3) + CODE + 6 (Latchkey), disarming
using a latchkey designated user code or keychain touchpad within an assigned
time schedule sends a page.
Refer to the User’s Guide for complete Latchkey setup and operation.
¾
To turn Latchkey Format off or on:
1. With the desired partition selected,
press A or B until the display shows
LATCHKEY FORMAT OFF/ON (current
setting).
2. Press 1 (off—basic) or 2 (on—
advanced). The display flashes the
entered setting. Press # and the dis-
play shows the new setting.
Freeze Alarm (partition 1: 06107, partition 2: 06207)
Reporting-Partition 1-2 (Default = off)
This setting determines whether the panel reports a freeze alarm to the
central station or pager, when the selected partition’s energy saver mod-
ule detects a temperature that matches a predetermined setting (see
BUS
DEVICES—UNIT ID—ENERGY OPTIONS—FREEZE TEMP
).
¾
To turn Freeze Alarm reporting off or on:
1. With the desired partition selected, press A or B
until the display shows
FREEZE ALARM OFF/ON
(current setting).
2. Press 1 (off) or 2 (on). The display flashes the
entered setting. Press # and the display shows
the new setting.
Alarm Verify (partition 1: 06108, partition 2: 06208)
Reporting-Partition 1-2 (Default = off)
This setting determines whether the panel reports to the central moni-
toring station after a single sensor or zone trip (off) or waits for a sec-
ond trip before reporting (on).
This setting affects sensors/zones in groups 10 through 20. If Alarm
Verify is set to on, group 18 responds the same as group 17 (see
“Appendix B, Table B1 “Sensor Group Characteristics”).
Note
For UL Listed installations, Alarm Verify must be set to off.
¾To turn Alarm Verify off or on:
1. With the display showing ALARM VERIFY OFF/ON
(current setting), press 1 (off) or 2 (on). The dis-
play flashes the entered setting.
2. Press # and the display shows the new setting.