DigitalFlow™ GF868 Programming Manual (1-Channel) 81
Chapter 6. Serial Communications
6.5.3b Wiring the System
After the serial interface converters have been configured for multi-point operation, the system can be wired.
1. Using twisted-wire pairs, connect the XMT+ terminals of all the flowmeters together and connect the XMT–
terminals of all the flowmeters together.
IMPORTANT: Make sure that the flowmeter with the non-modified converter is wired as the last unit in the chain.
2. Using a twisted-wire pair, connect the XMT+ terminal of the barrier strip to the T+/R+ terminal of the PC’s RS485
adapter and connect the XMT– terminal of the barrier strip to the T-/R- terminal of the PC’s 485 adapter (see the
documentation provided with the RS485 adapter for details).
Note: The XMT+ terminal on the barrier strip is the screw opposite the red wire connection and the XMT– terminal
on the barrier strip is the screw opposite the green wire connection.
3. Reinstall the clear plastic shroud, close the cover to the electronics console and reconnect the main power.
The RS485 serial interface is now ready for multi-point operation. However, the installed version of the Model GF868
software must be Version 3G or higher to support RS485 operation. If necessary, contact the factory for information
about a software upgrade.

Table of Contents

Other manuals for GE DigitalFlow GF868

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE DigitalFlow GF868 and is the answer not in the manual?

GE DigitalFlow GF868 Specifications

General IconGeneral
BrandGE
ModelDigitalFlow GF868
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals