42
High Limit Thermostat (Electric)
Oper at i ng Volt age: 240 VAC
Opens a t 308° + - 8°F
Cl oses at 2 48 ° + - 12 °F
Label Color: Purple
High Limit Thermost at Removal
1. Disconnect power from the unit .
2. Remove the drum.
3. Remove the high limit thermostat wires.
4. Remove the two 1/4 in. hex screws that hold the
high limit thermostat to the heater housing.
Inlet Thermostat (Electric)
Operating Voltage: 240 VAC
Opens a t 190° + - 5°F
Cl oses at 1 75 ° + - 5°F
Label Color: Red
El e c t r i c I n l et Th e r m o s t a t Re m o v a l
1. Disconnect power from the unit .
2. Remove the drum.
3. Remove the inlet thermostat wires.
4. Remove the two 1/4 in. hex screws that hold the
inlet thermostat to the heater housing.
Outlet Thermostat (Electric)
Oper at i ng Volt age: 240 VAC
Cl oses at 1 55 ° + - 5°F
Opens a t 165° + - 5°F
Label Color: Blue
El e c t r i c Ou t l e t Th er m o s t a t Re m o v a l
1. Disconnect power from the unit .
2. Remove the drum.
3. Remove the outlet thermostat wires.
4. Remove the two 1/4 in. hex screws that hold the
outlet thermostat to the blower housing.
See El ec t r i c H i g h Li m i t Th e r m o s t a t Lo c a t i o n o n
page 41.
See D r u m Rem o v a l o n p a g e 35 .
See El ec t r i c I n l e t Th e r m o s t a t Lo c a t i o n o n p a g e 4 1.
See D r u m Rem o v a l o n p a g e 35 .
See Ou t l e t Th e r m o s t a t Lo c a t i o n o n p a g e 17 .
See D r u m Rem o v a l o n p a g e 35 .