CHAPTER 7: ACCESS USING RADIUS ACCESS USING RADIUS
MULTILINK ML3000 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL 7–5
The reauth command determines how the authenticator (MultiLink switch) performs the
re-authentication with the supplicant or PC.
reauth port=<num|list|range> [status=<enable|disable>]
[period=<10-86400>]
The port argument is mandatory and sets the ports to be configured. The status argument
is optional and enables/disables re-authentication. The period argument is optional and
represents the re-authentication period. This is the time in seconds the authenticator waits
before a re-authentication process will be performed again to the supplicant. The default
value is 3600 seconds (1 hour), and values range from 10 to 86400 seconds.
The
show-stats command displays 802.1x related statistics.
show-stats port=<num>
The
trigger-reauth command manually initiates a re-authentication of supplicant.
trigger-reauth port=<num|list|range>