5–20 MULTILINK ML3000 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
IP ADDRESSING CHAPTER 5: IP ADDRESSING
FIGURE 5–4: Displaying configuration for different modules.
Note – multiple modules can be specified on the command line
5.4.4 Saving Configuration
It is advisable to save the configuration before updating the software, as it may be
necessary in certain situations. The
loadconf command requires a reboot to activate the
new configuration. Without a reboot, the ML3000 used the previous configuration. When
reboot is selected, the user is prompted as follows:
Reboot? ['Y' or 'N']
Select “Y”. The ML3000 will prompt:
Save Current Configuration?
Select “N”.
ML3000# show config module=snmp,system
[HARDWARE]
type= ML3000
slotB=8 Port TP Module
##########################################################
# System Manager - This area configures System related #
# information. #
##########################################################
[SYSTEM]
***Edit below this line only****
system_name=Main
system_contact=someone@joe.com
system_location= Markham, Ontario
boot_mode=manual
system_ip=192.168.1.15
system_subnet=0.0.0.0
system_gateway=192.168.1.11
idle_timeout=10
telnet_access=enable
snmp_access=enable
web_access=enable
--more—
...