15–8 MULTILINK ML3000 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
IGMP CHAPTER 15: IGMP
15.2.2 Example
The following example shows how to configure IGMP.
Example 15-1: Configuring IGMP
ML3000(igmp)## set-port port=10-12 mode=forward
Port mode is set.
ML3000(igmp)## show-port
---------------------
Port | Mode
---------------------
09 | Auto
10 | Forwarding
11 | Forwarding
12 | Forwarding
13 | Auto
14 | Auto
15 | Auto
16 | Auto
ML3000(igmp)## show-router
RouterIp PortNo Timer
---------------------------------
10.21.1.250 9 25