CHAPTER 7: ACCESS USING RADIUS ACCESS USING RADIUS
MULTILINK ML3000 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL 7–11
To change the port access characteristics when authenticating with a RADIUS server,
Select the Configuration > Radius > Port > Access menu item.
The Quiet Period column represents the time, in seconds, the supplicant is held after an
authentication failure before the authenticator retries the supplicant for connection. The
value ranges from 0 to 65535 seconds, with a default of 60.
The Max Reauth column shows the permitted reauthentication attempts before the port
becomes unauthorized. Values are integers ranging from 0 to 10, with a default of 2.