Appendix B. Modbus Communication
40 PanaFlow™ XMT1000 User’s Manual
92E Operator eDisplay_Unit
Type_ActVol
Unit type for actural
volumetric
unitless RW 4 INT32
930 Operator eDisplay_Unit
Type_StdVol
Unit type for standard
volumetric
unitless RW 4 INT32
932 Operator eDisplay_Unit
Type_Mass
Unit type for mass unitless RW 4 INT32
934 Operator eDisplay_Unit
Type_Totalizer
Unit type for totalizer unitless RW 4 INT32
936 Operator eDisplay_Unit
Type_TTAvol
Unit type for Actural
volumetric of totalizer
unitless RW 4 INT33
938 Operator eDisplay_Unit
Type_TTSvol
Unit type for Standard
volumetric of totalizer
unitless RW 4 INT34
93A Operator eDisplay_Unit
Type_TTMass
Unit type for Mass of
totalizer
unitless RW 4 INT35
93C Operator eDisplay_Unit
Type_Dens
Unit type for Density unitless RW 4 INT32
93E Operator eDisplay_
Contrast
Contrast for DISPLAY unitless RW 4 INT32
940 Viewer eDisplay_
Select_Decimal
_2ND
Select 2nd Display
Decimal
unitless RW 4 INT32
Display Real RO
A00
Display Int RO
B00 B00 N/A eDisplay_
Timeout_Max
Maximum TimeOut for
DISPLAY
13 RO 4 INT32
B02 N/A eDisplay_
Timeout_Min
Minumum TimeOut for
DISPLAY
13 RO 4 INT32
B04 N/A eDisplay_
Contrast_Max
Maximum Contrast for
DISPLAY
unitless RO 4 INT32
B06 N/A eDisplay_
Contrast_Min
Minimum Contrast for
DISPLAY
unitless RO 4 INT32
Log Real RW
C00
Log Int RW
D00 D00 Operator eLog_Control Log control / status unitless RW 4 INT32
D02 Operator eLog_Interval Log interval 13 RW 4 INT32
D04 Operator eLog_Time Logging time 13 RW 4 INT32
D06 Operator eLog_
numMonitor
Number of variables to log unitless RW 4 INT32
D40 D40 Operator eLog_
Va r ia b leVa lu e
variable address array unitless RW (4 * 25) INT32
D80 D80 Operator eLog_
VariableUnit
Variable unit code array unitless RW (4 * 25) INT32
Log Real RO
E00
Table 6: XMT1000 Modbus Register Map - Revision 4.19 (cont.)
Reg #
in Hex
Access
Level
Register ID Description Units RO/RW
Size in
Bytes
Format