PanaFlow™ XMT1000 User’s Manual 45
Appendix B. Modbus Communication
1A02 N/A eAout1_
ZeroValue_Min
Minumum Analog Out 1
Zero
8 RO 4 (IEEE 32 bit)
1A04 N/A eAout1_
SpanValue_Min
Minumum Analog Out 1
Span
8 RO 4 (IEEE 32 bit)
1A06 N/A eAout1_
TestValue_Min
Minumum Analog Out 1
Test Value (Percent of
Span)
12 RO 4 (IEEE 32 bit)
1A08 N/A eAout1_
BaseValue_Min
Minumum Analog Out 1
Base Value
1, 9, 14, 17,
20
RO 4 (IEEE 32 bit)
1A0A N/A eAout1_
FullValue_Min
Minumum Analog Out 1
Full Value
1, 9, 14, 17,
20
RO 4 (IEEE 32 bit)
HART Aout Min Real RO
1A10 1A10 N/A eAout2_
ErrValue_Min
Minumum Analog Out 2
Error Handling Value
8 RO 4 (IEEE 32 bit)
1A12 N/A eAout2_
ZeroValue_Min
Minumum Analog Out 2
Zero
8 RO 4 (IEEE 32 bit)
1A14 N/A eAout2_
SpanValue_Min
Minumum Analog Out 2
Span
8 RO 4 (IEEE 32 bit)
1A16 N/A eAout2_
TestValue_Min
Minumum Analog Out 2
Test Value (Percent of
Span)
12 RO 4 (IEEE 32 bit)
1A18 N/A eAout2_
BaseValue_Min
Minumum Analog Out 2
Base Value
1, 9, 14, 17,
20
RO 4 (IEEE 32 bit)
1A1A N/A eAout2_
FullValue_Min
Minumum Analog Out 2
Full Value
1, 9, 14, 17,
20
RO 4 (IEEE 32 bit)
IO Aout1 Min Real RO
1A20 1A20 N/A eAout3_
ErrValue_Min
Minumum Analog Out 3
Error Handling Value
8 RO 4 (IEEE 32 bit)
1A22 N/A eAout3_
ZeroValue_Min
Minumum Analog Out 3
Zero
8 RO 4 (IEEE 32 bit)
1A24 N/A eAout3_
SpanValue_Min
Minumum Analog Out 3
Span
8 RO 4 (IEEE 32 bit)
1A26 N/A eAout3_
TestValue_Min
Minumum Analog Out 3
Test Value (Percent of
Span)
12 RO 4 (IEEE 32 bit)
1A28 N/A eAout3_
BaseValue_Min
Minumum Analog Out 3
Base Value
1, 9, 14, 17,
20
RO 4 (IEEE 32 bit)
1A2A N/A eAout3_
FullValue_Min
Minumum Analog Out 3
Full Value
1, 9, 14, 17,
20
RO 4 (IEEE 32 bit)
IO Aout2 Min Real RO
1A30 1A30 N/A eAout4_
ErrValue_Min
Minumum Analog Out 4
Error Handling Value
8 RO 4 (IEEE 32 bit)
1A32 N/A eAout4_
ZeroValue_Min
Minumum Analog Out 4
Zero
8 RO 4 (IEEE 32 bit)
1A34 N/A eAout4_
SpanValue_Min
Minumum Analog Out 4
Span
8 RO 4 (IEEE 32 bit)
Table 6: XMT1000 Modbus Register Map - Revision 4.19 (cont.)
Reg #
in Hex
Access
Level
Register ID Description Units RO/RW
Size in
Bytes
Format

Table of Contents