Appendix B. Modbus Communication
46 PanaFlow™ XMT1000 User’s Manual
1A36 N/A eAout4_
TestValue_Min
Minumum Analog Out 4
Test Value (Percent of
Span)
12 RO 4 (IEEE 32 bit)
1A38 N/A eAout4_
BaseValue_Min
Minumum Analog Out 4
Base Value
1, 9, 14, 17,
20
RO 4 (IEEE 32 bit)
1A3A N/A eAout4_
FullValue_Min
Minumum Analog Out 4
Full Value
1, 9, 14, 17,
20
RO 4 (IEEE 32 bit)
MAIN Aout Min Int RO
1B00
MAIN Dout1 Real RW
2000 2000 Operator eDout1_
PulseValue
Output_1 Pulse Value 17 RW 4 (IEEE 32 bit)
2002 Operator eDout1_
PulseTime
Output_1 Pulse Time 10 RW 4 (IEEE 32 bit)
2004 Operator eDout1_
FreqBaseValue
Output_1 Frequency Base
Val ue
1, 9, 14, 17,
20
RW 4 (IEEE 32 bit)
2006 Operator eDout1_
FreqFullValue
Output_1 Frequency Full
Val ue
1, 9, 14, 17,
20
RW 4 (IEEE 32 bit)
2008 Operator eDout1_
AlarmValue
Output_1 Alarm Value 1, 9, 14, 17,
20
RW 4 (IEEE 32 bit)
200A Operator eDout1_
ControlValue
Output_1 Control Ouput
Val ue
17 RW 4 (IEEE 32 bit)
MAIN Dout1 Int RW
2100 2100 Operator eDout1_
PulseTestValue
Output_1 Test Pulse Value unitless RW 4 INT32
2102 Operator eDout1_
FreqFullFreq
Output_1 Frequency Full
Frequency
6RW4INT32
2104 Operator eDout1_
FreqTestValue
Output_1 Test Frequency
Val ue
6RW4INT32
2106 Operator eDout1_
FreqErrValue
Output_1 Frequency Error
Handling Value
6RW4INT32
2180 2180 Operator eDout1_Type Output_1 type unitless RW 4 INT32
2182 Operator eDout1_
PulseUnit
Output_1 Pulse Value Unit
Code
unitless RW 4 INT32
2184 Operator eDout1_
PulseErr
Output_1 Pulse Error
Handling
unitless RW 4 INT32
2186 Operator eDout1_
FreqAddress
Output_1 Frequency
Measument Register
Address
unitless RW 4 INT32
2188 Operator eDout1_
FreqErr
Output_1 Frequency Error
Handling
unitless RW 4 INT32
218A Operator eDout1_
FreqUnit
Output_1 Frequency Unit
code
unitless RW 4 INT32
218C Operator
eDout1_
AlarmState
Output_1 Alarm State unitless RW 4 INT32
218E Operator
eDout1_
AlarmType
Output_1 Alarm Type unitless RW 4 INT32
Table 6: XMT1000 Modbus Register Map - Revision 4.19 (cont.)