2–2 PQMII POWER QUALITY METER – INSTRUCTION MANUAL
CHAPTER 2: INSTALLATION
2.1.2 Product Identification
Product attributes vary according to the configuration and options selected on the
customer order. Before applying power to the PQMII, examine the label on the back and
ensure the correct options are installed.
The following section explains the information included on the label shown below:
FIGURE 2–2: Product Label
Model No: Shows the PQMII configuration. The model number for a basic panel
mount PQMII is “PQMII”. T20, C, and A appear in the model number only if the
Transducer, Control, or Power Analysis options are installed.
Supply Voltage: Indicates the power supply input configuration installed in the
PQMII. The PQMII shown in this example can accept any AC 50/60Hz voltage from
70 to 265 V AC or DC voltage from 90 to 300 V DC.
Tag#: An optional identification number specified by the customer.
Mod#: Indicates if any unique features have been installed for special customer
orders. This number should be available when contacting GE Multilin for technical
support.
Version: An internal GE Multilin number that should be available when contacting
us for technical support.
Serial No.: Indicates the serial number in numeric and barcode formats. Record
this number when contacting GE Multilin for technical support.
2.1.3 Manual and Firmware Revisions
Each instruction manual revision corresponds to a particular firmware revision. The
manual revision is located on the title page as part of the manual part number (the format
is 1601-nnnn-
revision). The firmware revision is located on that same page, just above the
manual part number, and is also loaded in the PQMII, where it can be viewed by scrolling
to the
A4 PRODUCT INFO ÖØ SOFTWARE VERSIONS ÖØ MAIN PROGRAM VERSION message.
When using the instruction manual to determine PQMII features and settings, ensure that
the instruction manual revision corresponds to the firmware revision installed in the PQMII.
20
19
18
17
16
15
141312
11
10
9
MAXIMUM CONTACT RATING
250 VAC 10A RESISTIVE
1/4HP 250VAC 1/2HP 125VAC
PQM II
MODEL NO.:
CONTROL VOLTAGE: SERIAL No.:
VERSION:
CUSTOMER TAG No.: 1234-567-89
90-300VDC 20VA
70-265VAC 50/60HZ 20VA
100.000
C7360001
PQMII-T20-C-A
MADE IN
CANADA
g