CHAPTER 4: SOFTWARE
PQMII POWER QUALITY METER – INSTRUCTION MANUAL 4–17
FIGURE 4–4: Data Logger Setup Window
1. The Log 1(2) Mode parameters are set as follows:
“Run to Fill”: when the data logger is full (100%) it will stop logging
“Circulate”: when the data logger is full, it will start from the beginning
and overwrite the previous data.
2. The Log 1(2) Interval parameters determine how frequently the PQMII logs
each piece of data.
3. The total log size is approximately 192KB. The allotment of this memory can
be varied between the two logs to maximize the overall log time. Set the Log
Size Determination to let the PQMII automatically optimize the memory. If
desired, the optimization can also be performed manually by the user.
4. The Log 1(2) Fill Time parameters represent the amount of time the data
logger takes to fill to 100%. This time is dependent on the logging interval and
the number of parameters being logged.
Z Set the parameters to be logged by setting the various Log Assignment
parameters to the desired log.
Z Select the Actual > Power Analysis > Data Logger > Log 1 (or Log 2)
item to view the respective data logger.