EasyManua.ls Logo

GE Reason RT430 - TTL Electrical Outputs; Open-collector electrical outputs

GE Reason RT430
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GPS Grandmaster Clock
36
RT430-TM-EN-5
2.10 TTL Electrical Outputs
RT430 has 4 electrical output, 2 screw connector, and 2 BNC connector. One output of each connector type
is insulated, as Figure 14 shows.
Figure 14: TTL level electrical outputs
See Chapter 1 for more description of signal levels and maximum charge.
The type of signal at each output can be configured through a Web Interface to generate IRIG-B004, DCF77,
1PPS, 1PPM, 100PPS, or any custom-defined low frequency, from 1 pulse-every-two-seconds to 1 pulse-
per-day. It is also possible to configure the outputs to generate daily set-time pulses. The polarity of the
signal can also be configured. For details on the configuration of TTL-Level electrical outputs, refert to
Chapter 4.
2.11 Open-collector electrical outputs
RT430 has 2 open-collector electrical outputs, shown in Figure 15.
Figure 15: Open collector electrical outputs
See Chapter 1 for description of signal levels and maximum charge.
The type of signal at each output can be configured through a Web Interface to generate IRIG-B004, DCF77,
1PPS, 1PPM, 100PPS, or any custom-defined low frequency, from 1 pulse-every-two-seconds to 1 pulse-
per-day. It is also possible to configure the outputs to generate daily set-time pulses. The polarity of the
signal can also be configured. For details on the configuration of open-collector electrical outputs, see
Chapter 4

Table of Contents