How to troubleshoot configuration or communication error on Gefran Inverter?
S
Shannon LynnSep 2, 2025
If the Gefran Inverter displays an error in the configuration stage or communication error, and if the first digit to the left of “H” in the alarm sub-code is equal to 0, the error relates to a communication problem. If the first digit to the left of “H” in the alarm sub-code is other than 0, the error relates to a configuration problem. For configuration errors, check the configuration of the Bus communication, Bus type, Baudrate, address parameter setting. For communication errors, verify wiring, resistance of terminations, interference immunity, timeout settings.
D
Darrell RiggsSep 14, 2025
What to do if Gefran Inverter displays Speed feedback loss alarm?
M
michael18Sep 14, 2025
If the Gefran Inverter displays a Speed feedback loss alarm, see parameter 2172 SpdFbkLoss code for information about the cause of the alarm and chapter 10.2 Speed fbk loss [22] alarm.
G
Gregg ThompsonAug 31, 2025
How to resolve intake air temperature too high alarm on Gefran Inverter?
M
Monica GarciaAug 31, 2025
If the Gefran Inverter displays an intake air temperature too high alarm, check correct fan operation.
J
James CarterSep 16, 2025
How to fix MDPLC application error on gefran ADP200?
L
lawrencegabrielleSep 16, 2025
Remove the MDPLC application or download a correct MDPLC application.
C
crystalcookeSep 15, 2025
What to do if gefran ADP200 shows error during loading of parameter database?
T
Terrence SmithSep 15, 2025
Set the parameters to the desired value and execute Save parameters.
R
Rebecca WeaverSep 23, 2025
What to do if gefran ADP200 Inverter shows Encoder error [ENCE]?
R
Ryan SmithSep 23, 2025
Take the recommended action for the Speed fbk loss alarm.
M
Molly BassAug 27, 2025
What to check if Gefran Inverter displays Ground fault [GNDF] alarm?
P
porterelizabethAug 27, 2025
If your Gefran Inverter shows a ground fault alarm, check the drive and motor wiring and check that the motor is not grounded.
D
David Scott MDAug 27, 2025
How to resolve braking resistor overload alarm on gefran ADP200 Inverter?
H
Harold DavisAug 27, 2025
If you're getting a braking resistor overload alarm on your Gefran Inverter, it means that the current absorbed by the resistor is greater than the rated current, or the overload threshold of the accumulator of the I²t braking resistor thermal image has been exceeded. You should:
- Check the size of the braking resistor.
- Check the condition of the braking resistor.
- Use a braking resistor with higher energy value and change the parameters on 22.5 - FUNCTIONS/BRES OVERLOAD menu.
M
Megan BrownAug 26, 2025
What causes motor overload alarm on Gefran Inverter?
C
Carolyn SweeneyAug 26, 2025
If your Gefran Inverter displays a motor overload alarm, it means the current absorbed during operation is greater than that specified on the motor data plate. To solve this:
- Reduce the motor load.
- Increase the size of the motor.
C
Carolyn VanceAug 25, 2025
Why gefran ADP200 shows DC link undervoltage alarm?
J
James WalkerAug 26, 2025
If your Gefran Inverter shows a DC link undervoltage alarm, check the connections. The problem is caused by the voltage arriving at the drive power section being too low compared to the Undervoltage [UV], the mains voltage being too low or overextended voltage drops, or poor cable connections (e.g. loose contactor terminals, inductance, filter).