Page #30 background imageLoading...
Page #30 background image
V 02/18
28 Initial start-up OptiStar CG08(-C)
6. Select parameter values according to the following table
No. Description
Values Display
P00
1)
Device type
0: Fluidizing device Type
F (CG13)
F
1: Box device with
vibrator Type B
(CG13)
B
2: Stirrer device Type S
(CG13)
S
3: Automatic device
(CG08/C)
A
4: Manual device with
fluidization (CG13)
S Fd
5: Application pump
(CG11-P)
P
6: Application pump +
CAN-Bus (CG12-CP)
CP
P02 Input pressure
0: P in = 5.5 bar
1: P in = 6 bar
2: P in = 6.5 bar
5.5
6.0
6.5
P03
Unit of
measurement
(air)
0: Nm³/h
1: scfm
P04 Interface type
0: Deactivated
1: Automatic
recognition
OFF
Auto
P05 CAN Baud rate
0: 20 kBit/s
1: 50 kBit/s
2: 100 kBit/s
3: 125 kBit/s
4: 250 kBit/s
5: 500 kBit/s
6: 800 kBit/s
7: 1 MBit/s
2 0
5 0
1 0 0
1 2 5
2 5 0
5 0 0
8 0 0
1 0 0 0
P06 CAN Node ID
1-127
P07 Reserve
P08 Reserve
P09 Reserve
P10 Log level
0, 1, 2, 3, 4, 5
LoG
1)
is not overwritten, if a Memory Reset is performed
Default values are marked by bold print.
7. Press
key to quit the system parameter mode
The display switches to the standard level