OptiStar CG08(-C) Initial start-up 29
System parameter P00
If the OptiStar CG08(-C) gun control unit is equipped with the CAN bus-
option, this device type is recognized automatically. The system
parameter P00 is set to 3 when device is starting.
NOTE:
A wrong parameterization leads to various malfunctions!
The system parameter P00 must be set to 3 (Automatic device)!
System parameter P03
This parameter is used to determine the measuring unit for all airs (total
air and electrode rinsing air). If the parameter is set to 1 (scfm), then all
air values are shown in this measuring unit. These lines are displayed in
blue.