33
Y N
Trouble diagnosis program for charge failure of battery
Battery can not
b
e char
g
e
d
Resistance is less
than standard value
Charge coil
shorte
d
Resistance is
infinite
Resistance conforms
to standard value
Charge coil or its
output conductor
opened
Set a multimeter to 0V
~
20V DC Voltage
range and then measure voltage between
conductor end (generally, red wire or
red/white wire) from connector to battery
and negative.
Circuit from magneto to rectifier
or rectification regulator contacts
poorly or opened
No voltage
dis
p
la
y
Voltage display
available
Conductor from
connector to
battery opened
Use an ohm meter to check
and measure rectifier or
rectification regulator for
malfunction
Disconnect bundle conductor of
magneto from connector of complete
vehicle cable and then use an ohm meter
to measure if resistance between output
conductor ends of charge coil conforms
to standard value
Connect bundle conductor of magneto with
connector of complete vehicle cable and
disconnect rectifier or rectification regulator from
connector of com
p
lete vehicle cable
Use an ohm meter to measure resistance between
output conductor ends of charge coil in connector
to see if it corresponds to self-resistance of charge
coil

Table of Contents