1.3.2 Charge
Connecting method
Connecting the positive pole of charger and the positive pole of
battery.
Connecting the negative pole of charger and the negative pole
of battery.
Warning
•Keep the battery away from ignition sources.
•Shut off the charger first once charge is started or finished so as to prevent explosion hazard caused by flashes at
the interconnecting part.
•Charge operation must follow the marked time on the battery.
*Attention
•Fast charging cannot be used except in contingency situations.
•Do not measure the voltage until 30 minutes after the charge.
Charging current Standard:0.4A
Fast:4.0A
Charging time Standard:10-15h
Fast:30m
Charge completedopen-circuit voltage12.8V or above
1.4 Charging system
1.4.1Short circuit test
Remove the ground wire off the battery, connect the voltmeter between the battery negative pole and ground wire
with the switch at OFF and inspect whether there is short circuit.
*Attention
Connect the positive pole of avometer with the negative pole of battery.
If there is any disorder, please inspect whether the main
switch and main wire are in short circuit condition.
1.4.2 Inspect the charging state
Test with an avometer when the battery is fully charged.
Mount the fully charged battery after the engine warms up.
Connect a voltage meter between the battery terminals.
Connect an amperemeter at the position where two terminals
Avomete
r