July 2019 Service and Repair Manual
Control System
Part No. 1286829GT S-40 XC • S-45 XC • S-40 TraX • S-45 TraX 27
Screen or Menu Item Default
Drive Ramps Standard Acceleration 5000 ms max, 100 ms min, 4000 ms (default)
Standard Deceleration 5000 ms max, 100 ms min, 1000 ms (default)
Torque Switching
Deceleration
5000 ms max, 500 ms min, 4000 ms (default)
Deutz D2.9
Anti-Stall
Threshold default = 2375 rpm
Drive Minimum default = 50%
Range default = 125 rpm
Hysteresis default = 100 rpm
Screen or Menu Item Default
Deutz D2011
Anti-Stall
Threshold default = 2500 rpm
Drive Minimum default = 60%
Range default = 700 rpm
Hysteresis default = 200 rpm
Screen or Menu Item Default
Perkins 404F
Anti-Stall
Threshold default = 2350 rpm
Drive Minimum default = 50%
Range default = 125 rpm
Hysteresis default = 100 rpm
Ford MSG425
Anti-Stall
Threshold default = 2375 rpm
Drive Minimum default = 85%
Range default = 125 rpm
Hysteresis default = 170 rpm