58 |G3 Owner’s Manual
DYN LEVEL & DYN TIME
Dyn Level determines how hard the G3 tries to suppress false triggers, whereas Dyn Time determines how long false
triggers are suppressed. For most pads with rubber playing surfaces, Dyn Level values between 8 and 15 and Dyn
Time between 8 and 20 should give the best results. For pads with fabric mesh heads, it may be necessary to in-
crease Dyn Time to over 20 and up to 60 as the skin diameter increases.
Dyn Level Parameter Value range: 0-15
Dyn Time Parameter Value range: 0-60 ms