Help in case of faults Instruction manual
66
10.2 Assignment of error codes
In case of a fault, the error codes will be displayed on the 7 segment display on the base board.
Error code
Description
“Ready-to-operate”
signal
EA response
----
No voltage No None
U
Voltage below specification No None
O
Housing internal
temperature too high (>80
°C)
No Stops
S
Time from end position
to end position too long (>
120s)
No Stops
Voltage above specification No Stops
Heating defective and T =
< 0 °C
No Normal
operation
e
Error in position detection No None
P
Invalid position No Normal
operation
E
Emergency manual override
active
No None
9
No communication with
accessories
No None
I
Actuator was run in motor
current limit
No Stops
Further error codes can be found in the corresponding accessory user manuals.