Reaction to interrupting of light beam
Door position Reaction to interrupting of light beam
CLOSE final limit position No action
OPEN-operation No action
OPEN final limit position
Without automatic closing
No action
OPEN final limit position
With automatic closing
Reset automatic closing
OPEN final limit position
With automatic closing
and interruption to timer
The door closes 3 seconds after the interruption period
for the light beam has ended
Extended photo cell function
Menu item "2.4“:
Function Extended photo cell function
„.0“ No action
„.1“ Cancel automatic
closing
The door closes 3 seconds after the interruption period for the
light beam has ended
„.2“ Vessel recognition
The door closes after the interruption period for the light beam
has ended, if the interruption period is longer than 1.5 seconds
Reset of automatic closing if the interruption duration for the
light beam is equal to or less than 1.5 seconds