MDE-LEDI-NETWORK-IN-4065V1.0
HARDWARE
The MIB describes which card is detected and what is the conguration for the cards.
All the output cards and the display are connected to a same output bus.
The different elds of this branch are described below:
ntpOutBusCardNumber
Number of cards detected on output bus.
ntpOutBusCardTable
A table that shows all the cards detected on the output bus. Each card is indexed by
its address (1..8 for output cards and 9 for the display). Each entry has the following
format:
ntpOutBusCardIndex:
Index of this entry (i.e card address). This value can have a value from 1 to 8 (for
output cards) or 9 (for display);
ntpOutBusCardState:
The state of the card. It can be detected that indicate that the card works cor-
rectly, failure if the card don’t reply or scrambled if the reply from the card is
incorrect;
ntpOutBusCardType:
Type of the card (see Erreur ! Source du renvoi introuvable. for a list of the
possible output cards types);
ntpOutBusCardDescription:
A textual description of the card;