MDE-LEDI-NETWORK-IN-4065V1.0
EXTERNAL SYNCHRONISATION INFORMATION
It gives information on an external time reference used by the hardware (for example
an antenna).
ntpSrvExternallySynchronized
notapplicable(2) if there is no information on external time reference
true(1) if the hardware is correctly synchronized on its external time reference
false(0) if the hardware is not synchronized on its external time reference (out of
radio coverture?)
ntpSrvSyncLostDuration
Number of seconds since beginning of synchronisation lose or duration of last syn-
chronisation lose
ntpSrvStratumLevel
Current stratum level. This is the value returned to the NTP client.
This value can change when the synchronisation is lost depending on the policy
dened in the setup.
Moreover, the default value can be changed through the setup.
ntpSrvLIValue
Current LI value. This is the value returned to the NTP client.
This value can change when the synchronisation is lost depending on the policy
dened in the setup.
ntpSrvAutonomous
true(1) if the NTP software is using its own clock to deliver time through the NTP
false(0) if the NTP software is using time code from its synchronisation input
ntpSrvAutonomous
If ntpSrvAutonomous=false, give number of seconds that the server can works
without time code at its input
If ntpSrvAutonomous=true, give number of remaining seconds before stopping
synchronizing equipment through NTP
Other texts are possible (for example when there is no possible autonomy)