Instructions
QUANTM
Pumps,
Industrial Models
Electric-operated diaphragm (EODD) pumps with an integral electric drive for fluid
transfer applications. Not for use with hygienic (sanitary) applications. Not for use with
gasoline. For professional use only.
Important Safety Instructions
Read all warnings and instructions in this
manual and related manuals before using
the equipment. Save these instructions.
i30 (QTC) Model
i80 (QTD) Model
i120 (QTE) Model
3A8572B
EN

Table of Contents

Questions and Answers

  • H
    Heather LeeAug 14, 2025
    Why does my Graco QUANTM i30 beep and show a yellow light?
    • N
      nathaniel10Aug 14, 2025
      If your Graco Water Pump emits a beeping alert sound and the LED light is yellow, it could be due to the pump starting its automatic startup sequence because it is connected to a power source while the control knob is not in the off position. To resolve this, turn the control knob to the off position or disconnect the power. Alternatively, if you intend to operate the pump, allow it to complete the automatic startup sequence.
  • M
    Mark CooperAug 18, 2025
    What to do if my Graco Water Pump suddenly stops working?
    • J
      johnnyliAug 18, 2025
      If your Graco Water Pump suddenly stops operating, it might be due to several reasons. A ground fault circuit interrupter (GFCI) might have tripped; if so, remove the controller from the GFCI circuit. There could be poor supply power, so check the connections and fix the source of the power problem. The equipment may have exceeded operational parameters. A leak sensor alert could also cause this issue, so check the diaphragm for rupture or incorrect installation, and repair or replace it if needed. Finally, the leak sensor might be disconnected, so ensure it is properly installed.
  • J
    Jordan BrownAug 21, 2025
    Why is my Graco QUANTM i30 performance reduced?
    • R
      Rodney DavisAug 21, 2025
      If your Graco Water Pump is experiencing reduced performance, it could be due to a clogged fluid line, which you should inspect and clear. Another possible cause is sticky or leaking checks, which should be cleaned or replaced. Lastly, a ruptured diaphragm (or backup diaphragm, if applicable) can also lead to reduced performance, requiring replacement.
  • F
    fwalkerAug 25, 2025
    What to do if my Graco Water Pump cycles but won't prime?
    • A
      Anthony PowersAug 25, 2025
      If your Graco Water Pump cycles but does not prime or pump, several factors could be at play. The equipment might be running too fast, causing cavitation before prime, so slow down the motor speed. The fluid may not be detected by the auto-prime sensor; ensure the suction end of the fluid supply line is inserted into the fluid and allow the auto-prime sequence to run for 30 seconds. A check could be worn or wedged in the seat or manifold, requiring replacement of the check and seat. There might be a restricted outlet or inlet port, which you should remove. Loose inlet fittings or manifolds should be tightened, and damaged manifold seats should be replaced.
  • N
    Nicholas HaleAug 28, 2025
    Why is my Graco QUANTM i30 Water Pump leaking fluid from joints?
    • J
      Jeffery VargasAug 28, 2025
      If you notice fluid leaking externally from the joints of your Graco Water Pump, it's likely due to loose manifold connections or fluid cover connections, which you should tighten. Alternatively, the manifold seats or seals may be worn, requiring replacement.
  • M
    Mr. Gary RobbinsAug 31, 2025
    Why won't my Graco QUANTM i30 hold fluid pressure?
    • J
      Jo ValenciaAug 31, 2025
      If your Graco Water Pump is not holding fluid pressure at stall, it could be due to worn checks, seats, or seals, which would need replacement. Another cause could be loose manifold connections or fluid connections, so tighten them. Lastly, a loose diaphragm shaft fastener could be the culprit, so ensure it is tightened.
  • K
    Kim RandolphSep 3, 2025
    Why are there air bubbles in the fluid from my Graco Water Pump?
    • A
      Ashley BrownSep 3, 2025
      If you find air bubbles in the fluid dispensed by your Graco Water Pump, it could be due to a loose fluid line, which needs tightening. A ruptured diaphragm (or backup diaphragm, if applicable) could also cause this, requiring replacement. Loose manifolds should be tightened using fasteners or clamps. Damaged seats or seals should be replaced. Lastly, a loose diaphragm shaft fastener should be tightened.
  • S
    Samantha KleinSep 6, 2025
    Why is my Graco QUANTM i30 Water Pump stalled and not cycling?
    • K
      keithmcclureSep 6, 2025
      If your Graco Water Pump is stalled and will not cycle, it could be due to a clogged fluid line or closed valves, which you should inspect and clear, also open valves downstream of the equipment. The motor or controller might be wired improperly, so wire per instructions in your related motor manual. A tripped leak sensor could also cause this, so check the diaphragm for rupture or incorrect installation, and repair or replace if necessary.
  • W
    whitney95Sep 9, 2025
    Why is my Graco QUANTM i30 Water Pump leaking fluid from the lower ports?
    • A
      Alexandra ThomasSep 10, 2025
      If you notice fluid leaking from the lower ports of your Graco Water Pump or find fluid on the floor, it is likely due to a loose diaphragm shaft fastener, which needs tightening. Alternatively, it could be caused by a diaphragm rupture or a leak in the equipment, requiring replacement.

Summary

Important Safety Instructions

Warnings

Hazard Categories

Covers fire, explosion, electric shock, misuse, entanglement, and toxic hazards.

Configuration Matrix

Model Configuration Details

Details on model part numbers, configuration sequences, and component materials.

Component Identification

Component Descriptions

Identifies key components for ordinary and hazardous location models.

Typical Installation

Installation Guides

Guides for installing pumps in ordinary and hazardous locations.

Installation

Mounting and Fluid Lines

Procedures for mounting the pump securely and connecting fluid lines.

Grounding Procedures

Essential steps for grounding the pump, fluid lines, and containers for safety.

Electrical Connections and Wiring

Power and Plug Requirements

Specifies power requirements and compatible plugs for different models.

I;O Pin Connection

Details the pinout and function of the M12, 5-pin connector for ordinary locations.

Operation

Startup, Adjustment, and Shutdown

Covers startup checks, adjustment, cavitation, and safe shutdown procedures.

LED Indicator

LED Indicator Overview and Troubleshooting

Explains LED status indicators and provides guidance for troubleshooting errors.

Maintenance

Preventive Maintenance Tasks

Covers schedule, inspection, tightening, lubrication, flushing, storage, and cleaning.

Troubleshooting

Common Problems and Solutions

Addresses issues like beeping alerts, no priming, pressure loss, and leaks.

Repair

Preparation for Repair

Steps to safely prepare the equipment before performing service or repair.

Repair the Check Valves

Detailed instructions for disassembling and reassembling check valves.

Repair the Standard Diaphragms

Procedures for disassembling and reassembling standard diaphragms.

Repair the Overmolded Diaphragms

Procedures for disassembling and reassembling overmolded diaphragms.

Recycling and Disposal

End of Equipment Life Procedures

Guidance on responsible disassembly, recycling, and disposal of the equipment.

Torque Fasteners

Torque Instructions and Sequence

Steps and sequences for properly torquing fasteners on fluid covers and manifolds.

Performance Charts

Pump Performance Data

Charts showing pressure vs. flow for i30, i80, and i120 models.

Dimensions

Model Dimensions

Drawings and tables with dimensional data for i30, i80, and i120 models.

Technical Specifications

Fluid Temperature Range and Model Specs

Specifies temperature ranges and detailed technical data for all models.

California Proposition 65

Health Warning

Warning regarding cancer and reproductive harm for California residents.

Graco Standard Warranty

Warranty Information

Details Graco's standard warranty terms and conditions for the equipment.

Graco QUANTM i30 Specifications

General IconGeneral
BrandGraco
ModelQUANTM i30
CategoryWater Pump
LanguageEnglish