Technical Specifications
3A8572B 51
Technical Specifications for i30 (QTC) Models
QUANTM i30 (QTC) Pumps
US Metric
Maximum fluid working pressure 100 psi 6.89 bar, 0.69 MPa
Maximum free-flow delivery 30 gpm 114 lpm
Maximum size pumpable solids 1/8 in. 3.2 mm
Environmental temperature range -4° to 104°F –20° to 40°C
Maximum operating altitude 9842 ft 3000 m
Electrical ratings
Rated Voltage Phase Hertz Current
i30 (QTC) models, FC1 motor 200–240 V 3 50/60 Hz 7.5 A
i30 (QTC) models, FC2 motor 200–240 V 1 50/60 Hz 10 A
i30 (QTC) models, FC3 motor 200–240 V 3 50/60 Hz 7.5 A
i30 (QTC) models, FC4 motor 200–240 V 1 50/60 Hz 10 A
i30 (QTC) models, FC5 motor 100–120 V 1 50/60 Hz 12 A
i30 (QTC) models, FC6 motor 100–120 V 1 50/60 Hz 12 A
Materials of construction
See Configuration Matrix, starting on page 7, for materials of construction for your equipment model.
Fluid inlet/outlet sizes
Models with wetted section materials coded:
AL, SS, HT 1 in. npt(f) or 1 in. bspt
CP, PP, PV 1 in. ANSI/DIN Raised Face Flange
Maximum suction lift*
Wet 29.0 ft 8.8 m
Dry 7.9 ft 2.4 m
Noise (dBa)
Maximum sound pressure 74 dBa at full power and flow
Sound pressure measured 1.6 feet (0.5 meter) from equipment.
Sound power measured per ISO-9614-2.
Weight
Models with wetted section materials coded:
AL 62 lb 28.1 kg
SS 79 lb 35.8 kg
HT 79 lb 35.8 kg
CP, PP 61 lb 27.7 kg
PV 67 lb 30.4 kg
Notes
* May vary based on pump materials, suction condition, discharge head, pressure, and fluid type.
All trademarks or registered trademarks are the property of their respective owners.