EasyManua.ls Logo

Graco QUANTM i30 - Technical Specifications for I30 (QTC) Models

Graco QUANTM i30
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Specifications
3A8572B 51
Technical Specifications for i30 (QTC) Models
QUANTM i30 (QTC) Pumps
US Metric
Maximum fluid working pressure 100 psi 6.89 bar, 0.69 MPa
Maximum free-flow delivery 30 gpm 114 lpm
Maximum size pumpable solids 1/8 in. 3.2 mm
Environmental temperature range -4° to 104°F –20° to 40°C
Maximum operating altitude 9842 ft 3000 m
Electrical ratings
Rated Voltage Phase Hertz Current
i30 (QTC) models, FC1 motor 200–240 V 3 50/60 Hz 7.5 A
i30 (QTC) models, FC2 motor 200–240 V 1 50/60 Hz 10 A
i30 (QTC) models, FC3 motor 200–240 V 3 50/60 Hz 7.5 A
i30 (QTC) models, FC4 motor 200–240 V 1 50/60 Hz 10 A
i30 (QTC) models, FC5 motor 100–120 V 1 50/60 Hz 12 A
i30 (QTC) models, FC6 motor 100–120 V 1 50/60 Hz 12 A
Materials of construction
See Configuration Matrix, starting on page 7, for materials of construction for your equipment model.
Fluid inlet/outlet sizes
Models with wetted section materials coded:
AL, SS, HT 1 in. npt(f) or 1 in. bspt
CP, PP, PV 1 in. ANSI/DIN Raised Face Flange
Maximum suction lift*
Wet 29.0 ft 8.8 m
Dry 7.9 ft 2.4 m
Noise (dBa)
Maximum sound pressure 74 dBa at full power and flow
Sound pressure measured 1.6 feet (0.5 meter) from equipment.
Sound power measured per ISO-9614-2.
Weight
Models with wetted section materials coded:
AL 62 lb 28.1 kg
SS 79 lb 35.8 kg
HT 79 lb 35.8 kg
CP, PP 61 lb 27.7 kg
PV 67 lb 30.4 kg
Notes
* May vary based on pump materials, suction condition, discharge head, pressure, and fluid type.
All trademarks or registered trademarks are the property of their respective owners.