Technical Specifications
3A8572B 53
Technical Specifications for i120 (QTE) Models
California Proposition 65
QUANTM i120 (QTE) Pumps
US Metric
Maximum fluid working pressure 60 psi 6.89 bar, 0.69 MPa
Maximum free-flow delivery 120 gpm 378.5 lpm
Maximum size pumpable solids 0.25 in. 6.35 mm
Environmental temperature range -4° to 104°F –20° to 40°C
Maximum operating altitude 9842 ft 3000 m
Electrical ratings
Rated Voltage Phase Hertz Current
i120 (QTE) models, FC1 motor 200–240 V 3 50/60 Hz 7.5 A
i120 (QTE) models, FC2 motor 200–240 V 1 50/60 Hz 15 A
i120 (QTE) models, FC3 motor 200–240 V 3 50/60 Hz 7.5 A
i120 (QTE) models, FC4 motor 200–240 V 1 50/60 Hz 15 A
Materials of construction
See Configuration Matrix, starting on page 7, for materials of construction for your equipment model.
Fluid inlet/outlet sizes
Inlet/Outlet size for models with wetted section
materials coded:
AL, CI. SS 2 in. npt(f) or 2 in. bspt
CP, PP, PV DIN PN16 050—2 in.
ANSI 150 2 NPS
JIS 10K 50
Maximum suction lift*
Wet 18.0 ft 5.48 m
Dry 15.9 ft 4.8 m
Noise (dBa)
Maximum sound pressure 77 dBa at full power and full flow
Sound pressure measured 1.6 feet (0.5 meter) from equipment.
Sound power measured per ISO-9614-2.
Weight
Models with wetted section materials coded:
AL 99 lb 44.9 kg
CI 165 lb 74.8 kg
SS 162 lb 73.5 kg
CP, PP 100 lb 45.4 kg
PV 117 lb 53.0 kg
Notes
* May vary based on pump materials, suction condition, discharge head, pressure, and fluid type.
All trademarks or registered trademarks are the property of their respective owners.
CALIFORNIA RESIDENTS
WARNING: Cancer and reproductive harm – www.P65warnings.ca.gov.