EasyManua.ls Logo

Graco Reactor 2 H-XP3

Graco Reactor 2 H-XP3
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Error Error
Error
Codes Codes
Codes
NOTE: NOTE:
NOTE:
Whenanerroroccursbesuretodeterminethecodebeforeresettingit.Ifyouforget
whicherrorcodeoccurred,seetheErrorsscreentoviewthelast200errors,withdate,time,and
description.
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
HoseResistance
Modeisselected
andTCM
hasbeen
replacedwithout
re-calibration.
Re-calibratethehose.
FollowtheCalibration
Procedure,page68.
05CH
ADM-
/TCM
Hosere-calibration
recommended
HoseResistance
Modeisselected
andADMhas
beenmoved
toanew
systemwithout
re-calibration.
Re-calibratethehose.
FollowtheCalibration
Procedure,page68.
Shortcircuitin
heaterwiring.
Checkwiringfortouching
wires.
A4DAHeaterA
HighCurrentA
BadHeater.
Conrmresistanceof
heater.Heaterresistance
shouldbe18–21Ωfor
eachheaterelement,
9–12Ωcombinedfor10
kWsystems,6-8Ωfor
15kWsystems,and4–6
Ωfor20kWsystems.If
outoftolerance,replace
heaterelement.
Shortcircuitin
heaterwiring.
Checkwiringfortouching
wires.
A4DBHeaterB
HighCurrentB
BadHeater.
Conrmresistanceof
heater.Heaterresistance
shouldbe18–21Ωfor
eachheaterelement,
9–12Ωcombinedfor10
kWsystems,6-8Ωfor
15kWsystems,and4–6
Ωfor20kWsystems.If
outoftolerance,replace
heaterelement.
Checkcontinuityof
transformerwindings.
Normalreadingsare
about0.2Ωonboth
primaryandsecondary.
Ifreadingisreplace
transformer.
A4DHHose
HighCurrentHoseShortcircuitin
hosewiring.
Checkforshortsbetween
theprimarywindingand
thesupportframeor
enclosure.
334946J
17

Other manuals for Graco Reactor 2 H-XP3

Related product manuals