Troubleshooting
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
Moduledoesnot
havesoftware
Insertasystemtoken
intotheADMmodule
andcyclethepower.
Waituntiltheupload
iscompletebefore
removingthetoken.
No24VDC
supplytomodule
Greenlightoneach
moduleshouldbelit.
Ifgreenlightisnotlit,
checktomakesureeach
CANcableconnectionis
tight.Verifythepower
supplyisoutputting24
VDC.Ifnot,checkpower
supplywiring.Ifwiringis
okay,replacethepower
supply.
CACTTCMTCMCommunica-
tionError
Looseorbroken
CANcable
ChecktheCANcables
runningbetweenGCA
modulesandtightenof
needed.Iftheproblem
stillpersistsmove
eachcablearoundthe
connectorandwatchthe
ashingyellowlighton
theGCAmodules.If
theyellowlightstops
ashing,replacetheCAN
cable.
Mixchambertoolarge
forsystemselected.Use
mixchamberratedfor
system.
Ensurethesystemhas
chemicalandthefeed
pumpsareoperating
correctly.
Nomaterialinpumps.
Verifypumpsare
supplyingchemical.
Ifnecessary,replaceor
relldrums.
DADX
HCM
PumpRunaway
Flowrateistoo
large
Inletballvalvesare
closed.Openballvalves.
ISOInletpressure
istoolow
IncreaseISOfeedpump
pressure.
F9FA
ADM
FlowCutbackLow
InletAPressure
ISOinletowis
toolow
ChangetolargerISOfeed
pump.