Troubleshooting
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
Modulefannot
operating
IfaTCMfanerror
(WMI0)hasoccurred,
faninsidethemodule
isnotworkingproperly.
CheckTCMfanfordebris
andclearwithforcedair
ifnecessary.
BadRTDorbad
RTDplacement
againstheater
SwapAandBheater
outputcablesandRTD
cablesandseeifissue
follows.Ifso,replace
RTD.
T4DAHeaterA
HighTemperature
A
Flowtoohigh
fortemperature
setpoint,causing
temperature
overshoots
whengunis
de-triggered
Useasmallermix
chamberthatisrated
fortheunitinuse.
BadRTDorbad
RTDplacement
againstheater
SwapAandBheater
outputcablesandRTD
cablesandseeifissue
follows.Ifso,replace
RTD.
T4DBHeaterB
HighTemperature
B
Flowtoohigh
fortemperature
setpoint,causing
temperature
overshoots
whengunis
de-triggered
Useasmallermix
chamberthatisrated
fortheunitinuse.
Hoseportion
exposedtoan
excessiveheat
source,likehot
sunorcoiled
hose,canpass
uidmorethan
27°F(15°C)over
hosetemperature
settingtotheFTS
Shadeexposedhosefrom
hotsunorexposeFTSto
sameenvironmentwhen
atrest.Uncoilentire
hosebeforeheatingto
avoidself-heating.
SettingtheA
orBsetpoint
muchhigherthan
hosesetpoint
cancauseuid
morethan27°F
(15°C)overhose
temperature
settingtoreach
theFTS.
Increasehosesetpoint
soitisclosertoAandB
setpoints.
T4DHHose
HighTemperature
Hose
334946J
31

Other manuals for Graco Reactor 2 H-XP3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco Reactor 2 H-XP3 and is the answer not in the manual?

Graco Reactor 2 H-XP3 Specifications

General IconGeneral
BrandGraco
ModelReactor 2 H-XP3
CategoryPaint Sprayer
LanguageEnglish

Related product manuals