Troubleshooting
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
Disconnectedor
looseRTDcable
orconnection
Checkallwiringand
connectionstotheRTD.
T6DA
HeaterA
SensorErrorA
BadRTDSwitchtheRTDwith
anotherandseeifthe
errormessagefollows
theRTD.ReplaceRTDif
theerrorfollowstheRTD.
Disconnectedor
looseRTDcable
orconnection
Checkallwiringand
connectionstotheRTD.
T6DB
HeaterB
SensorErrorB
BadRTDSwitchtheRTDwith
anotherandseeifthe
errormessagefollows
theRTD.ReplaceRTDif
theerrorfollowstheRTD.
T6DH
Hose
SensorErrorHose
Disconnected
orshortedRTD
cableinhoseor
badFTS
ExposeeachhoseRTD
connectiontocheckand
retightenanyloosecon-
nector.Measurehose
RTDcableandFTSconti-
nuity.SeeRepairHeated
Hose,page65.Order
RTDTestkit24N365for
measurement.
DisconnectthehoseRTD
anduseHoseManual
ModeorHoseResistance
Modetocontinuethejob
untilrepaircanbecom-
pleted.HoseResistance
Moderequiresasaved
calibrationfactor.Refer
toyourproportionerop-
erationmanualtoenable
HoseControlModes.
334946J