Troubleshooting
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
WMI0TCMTCMFanError
FaninsideTCM
isnotoperating
properly
Checkfordebrisinthe
TCMfanandclearwith
forcedairifnecessary.
WSUXUSB
CongurationError
USB
Avalid
congurationle
can'tbefoundfor
theUSB
Insetasystemtokeninto
theADMandcyclepower.
Waituntilthelightson
theUSBportstopashing
beforeremovingtoken.
WXUDADM
USBDownload
Error
Logdownload
failed
Backupandreformat
theUSBdrive.Retry
download.
WXUUADM
USBUploadErrorCustomlanguage
lefailedto
upload
PerformnormalUSB
downloadandusethe
newdisptext.txtle
touploadthecustom
language.
Hosesection
removedor
replacedwithout
re-calibration
Re-calibratethehose.
FollowtheCalibration
Procedure,page68.
Z1DH
Hose
LowResistance
HoseWire
Hosewire
temperatureis
toolow
Ensurehosewire
temperatureisabove
-4°F(-20°C).
Hosesection
addedor
replacedwithout
re-calibration
Re-calibratethehose.
FollowtheCalibration
Procedure,page68.
Z4DHHose
HighResistance
HoseWire
Hosewire
temperatureis
toohigh
Ensurehosewire
temperatureisbelow
221°F(105°C).
Z6DH
Hose
SensorErrorHose
Wire
TCMisunableto
sensehosewire
resistance
Ensureatleast50ft
(15.2m)ofheated
hoseisconnectedto
thesystem.
Iftheerrorcannot
beclearedorthe
errorregenerates
consistently,replace
TCM.