EasyManua.ls Logo

GRAPHTEC FC5100-130 - Page 141

GRAPHTEC FC5100-130
201 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Test Modes and Troubleshooting: Error Messages
140
The ESC character was followed by an
invalid byte.
Check the ESC command in your pro-
gram.
A device control command containing an
invalid byte was received.
Check the device control commands in
your program.
A parameter outside of the permissible
range was specified.
Check the parameter ranges in your pro-
gram.
Too many parameters were received. Check the number of command parame-
ters in your program.
During data trasnfer, a framing error, par-
ity error or overrun error occurred.
Check the settings of the interface condi-
tions.
The I/O buffer received data at a faster
pace than it could process indicating that
handshake was not successful.
Check the settings of the handshake
mode and other interface conditions.
Table 10: Error Messages in HP-GL Command Mode
Symptom Cause Solution
ERROR 11 INVALID
BYTE FOLLOWING ESC
ERROR 12 INVALID
BYTE IN I/O CONTROL
ERROR 13 OUT OF
RANGE I/O PARAMETERS
ERROR 14 TOO MANY
I/O PARAMETERS
ERROR 15 ERROR IN
I/O TRANSMISSION
ERROR 16 I/O BUFFER
OVERFLOW