GMV5 Home DC Inverter Multi VRF Units
4
Type of heat exchanger
-
Plate heat exchanger
Connection of
water system
Pipe diameter of water
inlet/outlet pipe
mm
Φ25
Specification of screw
thread
-
G1
Connection of
refrigerant system
Air pipe
mm
Φ15.9
Liquid pipe
mm
Φ9.52
High pressure air pipe
mm
Φ12.7
External dimension (W×H)
mm
500×919×328
Net weight
kg
56
2.3 Performance parameter of water tank
Model
SXVD200LCJ/A-
K
SXVD300LCJ/A-
K
SXVD350LCJ/A-
K
SXVD400LCJ/A-
K
Capacity
L
200
300
350
400
Consumed power for
electric heating
kW
3.0
3.0
3.0
3.0
Highest working pressure
MP
a
0.7
0.7
0.7
0.7
Inner pot
Material
-
SUS304L
SUS304L
SUS304L
SUS304L
Thickness
mm
1.5
1.5
1.5
1.5
Insulating
layer
Material
-
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Thickness
mm
50
45
45
45
External
layer
Material
-
Cold plate
Cold plate
Cold plate
Cold plate
Thickness
mm
0.8
0.8
0.8
0.8
Circulatin
g water
pipe
Pipe diameter
mm
DN20
DN20
DN20
DN20
Specification
of screw
thread
-
G3/4
G3/4
G3/4
G3/4
Cooling
water
inlet pipe
Pipe diameter
mm
DN15
DN15
DN15
DN15
Specification
of screw
thread
-
G1/2
G1/2
G1/2
G1/2
Hot water
outlet
pipe
Pipe diameter
mm
DN15
DN15
DN15
DN15
Specification
of screw
thread
-
G1/2
G1/2
G1/2
G1/2
External
dimensio
n
External
diamter×heig
ht
mm
Φ540×1595
Φ620×1620
Φ620×1895
Φ620×2125
Net weight of unit
kg
68
82
96
106
Model
SXVD200LCJ2/A
-K
SXVD300LCJ2/A
-K
SXVD350LCJ2/A
-K
SXVD400LCJ2/A
-K
Capacity
L
200
300
350
400
Consumed power for
electric heating
kW
3.0
3.0
3.0
3.0
Highest working pressure
MP
a
0.7
0.7
0.7
0.7
Inner pot
material
-
SUS304L
SUS304L
SUS304L
SUS304L
thickness
mm
1.5
1.5
1.5
1.5
Insulatin
g layer
material
-
Polyurethane
Polyurethane
Polyurethane
Polyurethane
thickness
mm
50
45
45
45