GMV5 Home DC Inverter Multi VRF Units
107
4.4.12. On/Off of Floor Heating
On/Off of floor heating: On the interface of floor heating, press ―ON/OFF‖ button, and floor
heating will be on or off.
On the interface of water heating: press ―WATER/AC/FLOOR‖ button once to activate the
interface of floor heating. After that, pressing ―ON/OFF‖ each time will switch floor heating on or
off.
4.4.13. Water Temperature Setting of Floor Heating
When floor heating is on, pressing ―▲‖ or ―▼‖ button will increase or decrease set
temperature by 1. Holding ―▲‖ or ―▼‖ button will increase or decrease set temperature by 1
every 0.3 seconds.
Temperature setting range for floor heating is 25~maximum water temperature for floor
heating. Default water temperature is 40.
Note:
1. Default maximum water temperature for floor heating is 45. Professional operators can
adjust the maximum water temperature from 40 to 52.
2. When floor heating water temperature auto setting function is effective, pressing ―▲‖ or ―▼‖
button will not change the water temperature.
4.4.14. Switch of Floor Heating Functions
The following functions can be set when floor heating is on or off: