Motion Delay
Suspends macro execution until a stable weight is achieved as determined by the settings for P114 (motion
divisions) and P115 (motion delay).
%
%
-
-
P
P
E
E
R
R
F
F
O
O
R
R
M
M
S
S
C
C
A
A
L
L
E
E
S
S
P
P
E
E
C
C
I
I
F
F
I
I
C
C
F
F
U
U
N
N
C
C
T
T
I
I
O
O
N
N
Syntax Perform Scale Specific Function
< ` | t | u | z > S < scale# > [ ;argument ] %-
Arguments
` Scale select
t Tare
u Units
z Zero
scale# Scale number (1 4).
argument Valid argument to the %`, %t, %u or %z command.
Notes
The %- command is mode independent. Use caution when using this command to ensure
the scale for which the function is intended will not be performing a critical function at the
time the function is executed.
This command replaces the mode independent commands previously available with the %`,
%t, %u and %z commands.
See Also
%` Scale Select
%t Tare
%u Units
%z Zero
Perform Scale Specific Function
Performs a mode independent scale-select, tare, units or zero function on a specific scale. These functions
can be performed on the currently selected scale as well as all other enabled scales regardless of the
current mode of operation. Motion delayed commands will be motion delayed for the intended scale
whether or not it is the currently selected scale. Commands that normally accept arguments such as ‘tare’
can also pass these arguments with the %- command.
M0%, Pause during motion on the currently selected
scale.
M1%, Pause during motion on scale 1.
M*%, Pause during motion on all scales. All scales
must be stable before macro execution will
resume.
M1;Mot'nDelay%, Display "Mot'n Delay" while pausing for motion on
scale 1.